User`s manual
Flgure 8X 8PC Log Report Showing Wed SLS Logging
___-___--__-___-________________________----------------------------------------
wa* 14, 1991 - 10:08:05
Page 1
Allen-Bradley Conlpany -- Smart Linear sensor --
SPC Log Report
Ajax Widget Co.
1234 nain street
center city, USA
__-__-__-__-____-_______________________-----*----------------------------------
Demcrlption : Part Width
lag File : TEST.ICG
________________________________________----------------------------------------
SLS on con1 Result A Result B Rpm"re The Cycle Time
________________________________________----------------------------------------
nean 60.64 60.14 12.2
25
Standard Deviation
0.34 0.16 0.0
0
Wax
69.74 60.63 12.2
30
win
67.84 59.73 12.2
25
=wle
1.90
0.90 0.0
5
Discrete output count
484 0
---
-_
Number of Triggers 484
Triggers Pmessed 484
Triggers Failed
0
________________________________________----------------------------------------
WC Charts Chart A Chart B
_---_---__-___-_____------------------------------------------------------------
Hean 68.64 60.14
Standard Deviation
0.34
0.16
Nax
69.74
60.63
nin 67.84 59.73
Range
1.90
0.90
Number of Points 464 484
l Statistics Report -This report is based on inspection
results that were saved during SPC operations using the
currently highlighted setup record. The report can
originate from run-only SPC operations, or from SPC
operations based on the short or long setup screen.
The report (Figure 8.27, page 8-63, and Figure 8.28,
page 8-64) contains a series of fields that account for alI
of the SPC statistics and parameter values used in the
CSS; however, not all of them are applicable in every
case. Non-applicable fields are marked “N/A.”
8-62