DataMyte ‘hrboSPC.PRN Format
When you select this Save Log function, the CSS converts
the SPC log into a file that you can import into the
DataMyte TurboSPC program. The converted file contains
basic inspection results data.
When the conversion is completed, a message appears with
instructions for importing the file into the DataMyte
TurboSPC program.
dBASE.DBF Format
When you select this Save Log function, the CSS converts
the SPC log to a dBASE.DBF file, each record of which
contains results data and other data from one SLS
inspection cycle.
Each record contains eleven fields, as follows:
Field 1 contains the COM port number to which the SLS is
connected, or a number representing the chart to which the
data applies (chart A = 5; chart B = 6).
Fields 2 and 3 contain the date and time of the trigger that
started the inspection cycle.
Field 4 contains the exposure time.
Field 5 contains the inspection cycle tune.
Field 6 contains the error LED status (‘IF’ = Off; 7” =
On).
Field 7 contains the contrast LED status (T’ = Off; “T’ =
On).
Field 8 contains the discrete output A LED status (“F’ =
Off; “T’ = on).
Field 9 contains the analog output A result.
Field 10 contains the discrete output B LED status (“F” =
Off, “T’ = On).
Field 11 contains the analog output B result.