User`s manual
Number of Cells
Use these fields to specify the number of cells in the
histogram for chart A and/or chart B. You can select the
same number of cells, or a different number, for each chart,
according to the requirements of your application. The
default number is 15 in a new setup record. The valid
numbers range from 5 to 30.
Stabilization Value
Use these tields to specify the number of individual
inspection results (data points) that the CSS uses to
“stabilize” the initial histogram boundaries. The boundary
settings are based on the minimum and maximum results
values received during the stabilization period.
The stabilization value should be large enough to include
the largest and smallest results values that am likely to
occur in your application. The valid numbers range kom 1
to 9999.
Number of Triggers Before Limit Change
Use these fields to specify the number of individual
inspection results (data points or “triggers”) that the CSS
must receive before it can change the histogram
boundaries. After receiving the specified number of
“triggers,” the CSS changes the boundary settings
whenever it receives a lower minimum value (or a higher
maximum value) since the last boundary change.
The valid numbers range ti-om 1 to 99.
The next group of data entry and option fields appear in
Figure 8.16 on page 8-39.
8-38