User`s manual

Flgure8.15 pChaiAtlribubzsMethodMenu
It
Result out of spec
Result above USL
Result below LSL
Discrete
output closed
You can select a menu option using either of the following
methods:
l Use the SPACE BAR to scroll down through the list of
options in the menu, or use the BACKSPACE key to
scroll up. In either case, the currently selected option
appears in the chart attributes field. Stop scrolling when
you see the correct option in the field.
l Press the TAB key. When you do this, the current option
(the one in the chart attributes field) is highlighted in the
menu. Use the down (or up) arrow key to highlight the
correct chart option, then press the ENTER key to select
that option.
Here are the options in the p Chart Attributes Method
Menu.
1.
2.
3.
4.
5.
Result out of spec - Use this option if the inspected
item is defective when the inspection result is outside
the upper or lower specification limit.
Result above USL - Use this option if the inspected
item is defective when the inspection result is outside
the upper specification limit only.
Result below LSL - Use this option if the inspected
item is defective when the inspection result is outside
the lower specification Limit only.
Discrete output closed - Use this option if the
inspected item is defective when the discrete output is
closed.
Discrete output open - Use this option if the inspected
item is defective when the discrete output is open.
8-37