User`s guide
SET NL
(NL)
Sets the NULL handler.
Format
SET NL condition
Condition
[NO]SYSGEN
SYSGEN causes NL to match the current monitor’s SYSGEN parameters. Issue
SET NL SYSGEN if you receive an error message indicating conflicting SYSGEN
options when you attempt to install NL.
NOSYSGEN inhibits NL from installing under the current monitor. SET NL
NOSYSGEN is useful when ST has been assigned the logical-device name NL
and you want to inhibit installation of the unnecessary NL.
[NO]TOY
SET NL TOY, the default, runs the NL handler installation code, if the RT–11
system is booted with the NLx.SYS handler present on the system disk or if the
NL handler is removed and installed with DCL commands.
The NL installation code transfers date and time information from the KDJ11–E
Time-Of-Year (TOY) clock to the resident monitor. You might want to include
this command in your STRTxx.COM file.
SET NL NOTOY prevents the NL handler from transferring the current date
and time to the resident monitor.
Description
The KDJ11–E clock keeps the current date and time; both the PDP–11/93 and 11/94
processors contain this clock.
While the SET NL TOY transfers date and time information from the KDJ11–E
clock to the resident monitor, the SETUP command sets the date and time.
Issue the SETUP [CLOCK] DATE and SETUP [CLOCK] TIME commands to set the
specified date and time for both the monitor time and the time-of-year clock in a
PDP–11/93 and 11/94 processor.
258 RT–11 Command Descriptions