NOTE: The Quiet Slot DELTA Time must be set to 10 on all systems in a
cluster when any one system uses a CIXCD adapter. This is required.
For new systems just being installed, manufacturing should have jumpered
pins E45 and E15. Check the backplane at segment E. Jumper these pins if
they are not already jumpered.
Table 4–4: Quiet Slot Time Backplane Jumpers
Quiet
Slot Count
W28
E13/43
W29
E14/44
W30
E15/45
7 OUT OUT OUT
10 OUT OUT IN
Reserved OUT IN OUT
Reserved OUT IN IN
Reserved IN OUT OUT
Reserved IN OUT IN
Reserved IN IN OUT
Programmable IN IN IN
Connecting to a CI VAXcluster 4–11