Installation guide

Run the VAX Diagnostic Supervisor, and then load and run EVCXF.
Enter the START/SECTION=TEST2 and the SIZE commands, as shown
in Example 3–3. Then proceed to change the node ID with the information
as shown in Example 3–4 with the command string
DS> SET NODEID XMI NODE 5, DSSI BUS 1, NEW DSSI NODE ID 6
where:
5 is the XMI node and slot where the KFMSA resides that is going to
have its node ID changed.
1 is the bus on the KFMSA whose node ID is going to be changed
6 is the new value being entered for the node ID of bus 1 on the KFMSA
residing in XMI slot 5.
This string repeats the node ID change to 6 for bus 2 on the same
KFMSA.
FOR MORE INFORMATION
Primary reference: KFMSA Module Installation and User Manual
Secondary reference: SF2xx Storage Array Installation Guide
Connecting to a DSSI Subsystem 3–41