Installation guide
Table 3–2: DSSI Installation
Location Single-Host Configuration
1
DSSI VAXcluster
1
Cable Installation
ISE in VAX 6000 No change. All cables are fac-
tory installed.
Attach cables from SF7x to ad-
ditional host systems. †
ISE in SF2xx
storage array cabinet
Attach cables from host system to SF2xx cabinet.
2
Bus Termination
Host I/O bulkhead Install termination on each unused connector as neces-
sary.
SF7X Enclosure Box Install termination on eachunused connector on rearpanel, as nec-
essary.
Node ID Settings
KFMSA No change. Leave at factory set-
ting of node ID 7.
Set second host node ID to 6
and third host to 5.
3
ISEs No change. Should be correctly set at factory.
Tapes are set to node ID 0; through-bus SF7x boxes are
node IDs 1 to 4. split-bus SF7x boxes (for single- and dual-
host) are node IDs 5 and 6.
ISE Parameter Changes
ISEs See KFMSA Module Installation and User Manual for explicit di-
rections on changing parameters.
Adding Hosts to Existing DSSI Subsystems
New and original hosts Reconfigure DSSI storage bus, setting node IDs, termina-
tion, and possibly changing split-bus.
1
Assumes a new installation only; does not apply to add-on configurations.
2
See the SF2xx Installation Manual for complete cabling instructions.
3
See the KFMSA Module Installation and User Manual for changing node IDs.
†These callouts refer to the manuals listed in Table 3–1.
Connecting to a DSSI Subsystem 3–3