Installation guide
If you are using tape for verification, use the diagnostic tape, part
number:
AQ-PDWX*-DE - VAX 6000 CMPLT DIAG TK50
^
|
+---- Revision letter in this position
(initial revision=A)
If you have more than one tape, use the one with the most recent
revision level. Insert the diagnostic tape in the tape drive, write-
protected.
Enter the BOOT command as shown in Example 8–5.
The /R5:10 qualifier selects the VAX Diagnostic Supervisor program.
CSA1 is a special boot specification for the console device (TF or TK).
CSA1 is defined on all VAX 6000 systems to look first for a console load
device in the cabinet and then for a TF857 tape in an SF2xx storage
cabinet.
The self-test display and VAX Diagnostic Software banner appear,
followed by the Diagnostic Supervisor banner. Then the VAX Diagnostic
Supervisor runs and issues its prompt.
Different file names appear here, depending on the VAX 6000 model
number.
Table 8–2: VAX/DS File Names
Model Number File Name
Model 600 EXSAA
Model 500 EMSAA
Model 400 ERSAA
Model 300 ELSAA
Verification 8–19