Put a blank cartridge in the TK drive. Check that it is not write-
protected. The blank tape is required for proper running of the RBDs.
(If you are unfamiliar with the tape drives, see the VAX 6000 Series
Owner’s Manual.)
In this example, the DWMBB adapter is XMI node E. The TK
controller (TBK70) is VAXBI node 4.
Enter the Z command, using the /BI qualifier. The system console
communicates with the module at VAXBI node 4 on the VAXBI whose
adapter is at XMI node E. The system responds to the Z command with
a message.
Enter the command T/R to invoke the module’s ROM-based diagnostic
monitor.
The diagnostic monitor prompt is RBD4>, where 4 is the VAXBI node
number. Enter the command D2/TR/T=6/C. The diagnostic performs a
read/write test.
The diagnostic prints out several lines of information. Check for a P
in the first field of the diagnostic completion message, which indicates
that the test passed.
Enter QUIT, which stops execution of the ROM diagnostic monitor and
resets the controller.
Enter CTRL/P, which reattaches the console to the boot processor. The
system responds to CTRL/P with a message.