Installation guide

The TYP line in this printout indicates that adapters in this
configuration are in XMI slots D and E. Slot E was chosen as the slot
for the DWMBB/A adapter module.
Because the DWMBB adapter does not have a module-resident self-test,
its entry for the STF line will always be "o".
The test results for the DWMBB/A and DWMBB/B modules are
indicated on the XBI line, at the far right. In this example, the DWMBB
modules have passed self-test (XBI E +). The results of the VAXBI I/O
adapter self-tests are shown in columns 0 through F, which stand for
the VAXBI node numbers; in this configuration, node numbers 1, 2, 3,
4, and 6 are used. All VAXBI modules have passed.
Note that XMI entries use only slots 1 through E, while the VAXBI can
have entries in slots 0 through F. An XMI slot and node number are the
same; VAXBI slot and node numbers are not identical. Node plugs (labeled
1 to 12) in the backplane of the VAXBI are used to identify the number of
a node.
System Self-Test 7–7