Installation guide
Table 4–7: CIBCA Address Jumpers on VAXBI Backplane
CI Node
Address
D5–35
E1–31
D6–36
E2–32
D7–37
E3–E33
D8–38
E4–34
D9–39
E5–35
D10–40
E6–36
D11–41
E7–37
D12–42
E8–38
0 OUT OUT OUT OUT OUT OUT OUT OUT
1 OUT OUT OUT OUT OUT OUT OUT IN
2 OUT OUT OUT OUT OUT OUT IN OUT
3 OUT OUT OUT OUT OUT OUT IN IN
4 OUT OUT OUT OUT OUT IN OUT OUT
5 OUT OUT OUT OUT OUT IN OUT IN
6 OUT OUT OUT OUT OUT IN IN OUT
7 OUT OUT OUT OUT OUT IN IN IN
8 OUT OUT OUT OUT IN OUT OUT OUT
9 OUT OUT OUT OUT IN OUT OUT IN
10 OUT OUT OUT OUT IN OUT IN OUT
11 OUT OUT OUT OUT IN OUT IN IN
12 OUT OUT OUT OUT IN IN OUT OUT
13 OUT OUT OUT OUT IN IN OUT IN
14 OUT OUT OUT OUT IN IN IN OUT
15 OUT OUT OUT OUT IN IN IN IN
16 OUT OUT OUT IN OUT OUT OUT OUT
17 OUT OUT OUT IN OUT OUT OUT IN
18 OUT OUT OUT IN OUT OUT IN OUT
19 OUT OUT OUT IN OUT OUT IN IN
20 OUT OUT OUT IN OUT IN OUT OUT
21 OUT OUT OUT IN OUT IN OUT IN
22 OUT OUT OUT IN OUT IN IN OUT
23 OUT OUT OUT IN OUT IN IN IN
Connecting to a CI VAXcluster 4–23