User`s guide

The
xx
in
the error message shown
in
Example 4-4
is
the hex error code shown in Table 4-3.
The microdiagnostic error printout
in
Example 4-5
is
explained below:
o
o
e
o
e
o
o
o
Diagnostic section
in
which an error occurred
Test number within
that
diagnostic section
Error number. Within a particular test, several pieces
of
hardware may be tested, each by a
subtest. The error number identifies the unique subtest that failed.
Expected correct data
Received
data
OTHER
field
will
contain
N/
A (not applicable) or pertinent data. When data
is
present, the
errors section of the test listing on microfiche
will
define the data.
MASK
is
the error mask used to check the result. Bits set to a 1
in
this mask correspond to bits
in
the
result that are not checked.
MODOLE
is
the suspected failing module.
Table 4-3 MICMON
Error
Code List (Hex)
Error
Code Definition
01
02
03
04
10
11
22
23
24
25
26
27
28
29
2A
30
31
32
Board not found.
No
test number found.
No
pass count found.
Continue not available
at
this point.
No
address or no
data
input with command.
No
WCS
image for exam or deposit routine.
Examine or Deposit main memory reports error.
Sequence error in
WCS
testing or nonexistent test.
Timeout error in
WCS
testing.
TU58
error.
Parity error in WCS.
Checksum error in
MICMON.
DI
TE
attempted with possible invalid test code loaded (do DI
SE
or DI BO).
UPC
does not
match
on verify
of
32 bit data write.
INIT
done without file loaded.
Checksum error in X command.
No
X command address found.
No
X command count found.
4-6