User guide

Taking care of your machine
Replacing the hard water lter
Pull to remove the hard
water lter.
New lter (beige/cream
colour).
Hard water lter should
be replaced every 3 to 6
months or if discoloured.
Remove the water tank
to access the hard
water lter.
To remove the water tank
press both water tank
release buttons, and pull
to remove.
Emptying the water/detergent tanks
Pull the tab on the water
tank to open.
Using your foot, hold the corner
of the microbre cleaning pad
down, lift steamer to peel away.
The microbre pad is machine wash-
able (Max 40⁰C) allow to fully dry
before use.
Wrap the power cord around the
quick cord release hooks and insert
the plug into the plug storage socket.
Removing cleaning pads Storing your steamer
Taking care of your machine
Max 40°C
IMPORTANT: Allow the steamer to fully cool down before performing any maintenance or troubleshooting checks. Don’t leave water or
detergent in the tanks between uses, as this can eect the steamer’s performance, the water/detergent tanks need to be emptied and
rinsed after each use.
IMPORTANT: Don’t use bleach or fabric softener when washing the microbre cleaning pad. Always allow the steamer to fully cool
down before removing the microbre cleaning pad.
Empty any excess water
over the sink.
Rinse water tank with water and
replace water tank tab, push rmly
to close before replacing back onto
the steamer.
Press the release buttons
and pull the detergent
tank to remove.
Emptying the detergent tank
Twist detergent tank cap
anti-clockwise and lift to
remove.
Empty any excess
detergent over the sink.
Rinse detergent tank with water,
replace detergent tank cap and turn
clockwise to tighten. Replace the
detergent tank back onto the steamer
3-6 Months
IMPORTANT: Don’t operate the steamer without hard water lter in place. The condition of the lter aects the performance of your
steamer, check and change lter periodically. If you live in a hard water area the lter will discolour or darken over time. Depending on
water hardness and frequency of use, the lter should be changed every 3 to 6 months (or if the lter has discoloured)
If there is an obstruction
to the steam ow through
the machine, steam may be
released through the bleed
valve located on the side of
the handheld.
With the pad removed from
the oor head, insert a
small thin object such as
a paper-clip in to the steam
holes to remove a blockage.
To remove the oor head
from main body push the
oor head release button
and lift.
After oor head is removed,
using a thin object such as
a paper-clip (in the area
shown), insert to remove
the blockage.
Removing blockages