Specifications
3-12 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Platinum VAX-C Series
3.2.3 Configuration Screens 
Figure 3-9 System Configuration Screens 1 & 2
Table 3-6  Xmtr Home>Config
Field Explanation
Fwd Low Pwr 
Warning
Set the minimum forward power in watts (W) below which a warning is 
indicated. If the transmitter output power drops below this level, the forward 
power bar and Output LED will turn yellow. This value must be lower than 
Nominal power.
Fwd Low Pwr Alarm Set the minimum forward power in watts (W) below which a fault is indicated. 
If the transmitter output power drops below this level, the forward power bar 
and Output LED will turn red. This value must be lower or equal to the FWD 
Low PWR Warning.
Max Fwd Power Set the maximum forward power in watts (W) above which a fault is indicated. 
If the transmitter output power exceeds this level, the forward power bar will 
turn Red. This value must be larger than the Nominal Power Output.
Nominal Power 
Output
This entry sets the maximum level that the Fwd Power Reference can be set to 
in watts (W), and also sets the 100% forward power bar level.
Actual Fwd Power 
Ref
This field represents the actual power setting in the transmitter. The actual 
power setting can be reduced from the Fwd Power Reference setting due to 
any of the following reasons:
- The value of the % of Fwd Pwr Reference setting is less than 100%.
- Faulted PA components have reduced the maximum output power of the 
system below the Fwd Pwr Reference setting.
- Transmitter is in power foldback state due to a high level of reflected power 
at the transmitter output.