Specifications

2-12 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
Platinum VAX-C Series
NOTE:
The alarms noted in the above table report the following functions and are
mapped to the Front Panel LEDs as follows:
Alarm 0: Output/Mute (If either Output or Mute LED is RED or ORANGE,
Alarm is Faulted.)
Alarm 1: System (If System LED is RED or ORANGE, Alarm is Faulted.)
Alarm 2: Power Supply (If Power Supply LED is RED or ORANGE, Alarm
is Faulted.)
Alarm 3: Drive Chain/Power Amp (If either Drive Chain or Power Amp
LED is RED or ORANGE, Alarm is Faulted.)
Alarm 4: TS Input (If TS Input LED is RED or ORANGE, Alarm is
Faulted.)