5/9/13 888-2857-001 2-7
WARNING: Disconnect primary power prior to servicing.
Section 2 Installation / Initial Turn-On
Platinum VAX-C Series
2.6.4 Cabinet Ground Strap
Connect a ground strap from the cabinet's copper ground buss bar (shown in Figure 2-2)
to the station ground. The copper strap must be at least 5cm wide and 0.5mm thick. To
prevent ground loops, do not connect this strap to the ground of another piece of
equipment, but instead, connect directly to the main station ground system.
Figure 2-2 Typical Cabinet Ground Strap Connection
2.6.5 Connecting AC Power
!
CAUTION:
CHECK THE AC POWER THAT WILL FEED THE VAX-C. IT MUST BE BETWEEN 100
VAC AND 240 VAC +/-10%. ANY VOLTAGE OUTSIDE THIS RANGE WILL CAUSE
DAMAGE TO THE EQUIPMENT. THE VOLTAGE SHOULD BE MEASURED LINE TO
LINE, OR IF A NEUTRAL IS USED, LINE TO NEUTRAL.
!
WARNING:
AN EXTERNAL CIRCUIT PROTECTION DEVICE (BREAKER OR FUSE) IS REQUIRED
FOR EACH COMPONENT AC INPUT. THIS IS PROVIDED BY THE CUSTOMER IN
ACCORDANCE WITH THE AC INTERCONNECT DRAWING OR BY HARRIS IF AN IN-
RACK AC DISTRIBUTION CHASSIS IS PURCHASED (OPTIONAL). IN THE LATTER
Connect Ground
Strap Here and to
Station Ground