Platinum VAX-C transmitters include a Web enabled remote GUI interface that
provides comprehensive remote control and monitoring of data points within the
transmitter. It includes an SNMP (simple network management protocol) manager
which allows integration with most control systems via the Internet or LAN.
1.6 Operating Voltages
Single phase, 100 to 240 V AC, auto-ranging, +/-10%, 50/60 Hz, one IEC C15 inlet.
!
CAUTION:
CHECK THE AC POWER FEEDING THE VAX-C. IT MUST BE BETWEEN 100
VAC AND 240 VAC +/-10%. ANY VOLTAGE OUTSIDE THAT RANGE WILL
CAUSE DAMAGE TO THE EQUIPMENT. THE VOLTAGE SHOULD BE
MEASURED LINE TO LINE, OR WHEN A NEUTRAL IS USED, LINE TO
NEUTRAL.
!
CAUTION:
IF VOLTAGE VARIATIONS IN EXCESS OF +/-10% ARE ANTICIPATED, THE
TRANSMITTER POWER INPUT MUST BE EQUIPPED WITH AUTOMATIC VOLTAGE
REGULATORS (OPTIONAL EQUIPMENT) CAPABLE OF CORRECTING THE MAINS
VOLTAGE.