Specifications

5/9/13 888-2857-001 6-5
WARNING: Disconnect primary power prior to servicing.
Section 6 Diagnostics
Platinum VAX-C Series
Modulator
25MHz Clock
Indicates 25 MHz clock is
present in MOD FPGA
System and Mute
LEDs red.
25 MHz clock edges
are detected
25 MHz clock edges are not
detected
Modulator
54MHz Clock
Indicates 54 MHz clock is
present in MOD FPGA
System and Mute
LEDs red.
54 MHz clock edges
are detected
54 MHz clock edges are not
detected
Modulator User
Force Mute
Indicates user has forced
mute from GUI
System and Mute
LEDs red.
Mute not selected on
GUI
Mute selected on GUI
Table 6-3 MODFPGA Modulation Specific Faults
Fault Log Message Fault Description Front Panel LEDs
Nominal Value/
Scaling
Trip Level
DVB (modulation specific)
ASI 1 HP Indicates error on
ASI 1 HP in MOD
FPGA for DVB
System LED red. No errors Input present:
Uncorrected byte errors,
Corrected byte errors,
Buffer overflow,
MIP errors ((CRC error OR MIP
missing) AND (SFN or MFN AND
MIP control))
Input not present:
ERRW_MODFPGA_PRBS_ON
=false
ASI 1 LP Indicates error on
ASI 1 LP in MOD
FPGA for DVB
System LED red. No errors Input present:
Uncorrected byte errors,
Corrected byte errors,
Buffer overflow
Input not present:
Hierarchy mode AND
ERRW_MODFPGA_PRBS_ON
=false
ASI 2 HP Indicates error on
ASI 2 HP in MOD
FPGA for DVB
System LED red. No errors Input present:
Uncorrected byte errors,
Corrected byte errors,
Buffer overflow,
MIP errors ((CRC error OR MIP
missing) AND (SFN or MFN AND
MIP control))
Input not present:
ERRW_MODFPGA_PRBS_ON
=false
Table 6-2 MODFPGA Faults
Fault Log
Message
Fault Description Front Panel LEDs
Nominal Value/
Scaling
Trip Level