Specifications

5/9/13 888-2857-001 5-59
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
5.17.3 Inputs/Outputs
Two ETI, BNC, 75 ohm, female inputs - labeled ETI1 IN and ETI2 IN
One ETI, BNC, 75 ohm, female output - labeled ETI MON
Two 10/100 BaseT network, RJ45 ports on the rear panel - labeled ETH1 and ETH2
Three SMA, 50 ohm, female outputs - labeled 2.048 MHz-Out, SYNC ETI Out, &
SYNC OFDM Out
5.17.4 Operation
One EDI stream can be processed by the EDI board along with one ETI stream. If EDI
is not used then two ETI input streams can be used. The multiplexer sends EDI data to
the IP address of the EDI board. The processor on the EDI board receives the EDI data,
converts it to an ETI stream, and outputs the ETI stream to the DAB modulator.
5.17.5 M2X, LPU or VAX Interface
Interface
EDI per ETSI TS 102 693 V1.1.2
1x Channel
10/100 BaseT (RJ45)
Protocols
UDP/DCP
TCP/DCP
Processing
1x Stream (ETH2)
Forward Error Correction (RS) Code Strength 1-5 (auto-detecting)
SFN preservation
Adjustable buffer depth
Control and Management
Exciter screens for IP setup
In-system programmable over ETH1 interface