Specifications
5-52 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
5.15 Connecting to the VAX via SNMP
The VAX-C transmitter family supports monitoring and alarming functionality via
SNMP (Simple Network Management Protocol). Basic control of the equipment is
possible after activation in the equipment. SNMP versions V1 and V2c and V3 are
implemented.
This section assumes a good working knowledge of networking and SNMP
connectivity. The information contained here is not meant to teach networking or how
to setup/operate a network manager application, but merely provide the information
necessary for a network administrator to connect and operate the VAX-C transmitter
using the SNMP connection.
5.15.1 SNMP Configuration
Setup for SNMP operation is done via the web browser by navigating to the VAX-C
SNMP setup screen. Press Exciter Home > Setup > Remote Communications > NEXT
> NEXT.
Figure 5-26 LPU SNMP Setup Screen
The SNMP setup screen allows location setting for connection identification,
destination IP address for trap messages, R/W community, Enable/Disable of Set
commands, Port, selection of V1 or V2 traps and deletion of IP addresses.