Specifications
5/9/13 888-2857-001 5-49
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
Figure 5-23 Bootloader Browse Screen
STEP 4 Highlight the desired file then press Open.
STEP 5 The bootloader ISP screen will be displayed and the ’File to Update:’
window will display the filename. Press ’Submit’. The update will take
several minutes. Do not disrupt the process.
STEP 6 Upon completion of the process open a web browser session to
reestablish the connection to the VAX-C transmitter.
STEP 7 End of procedure.
In instances where the IP address is unknown or when the above procedure fails the
following procedure may be used:
STEP 1 Connect a serial cable from PC / laptop to the VAX-C.
STEP 2 Start a terminal program (115,200,N,8,1) and make sure it is the active
PC window/program.
STEP 3 Hold down the escape (ESC) key and power cycle the transmitter by
either plugging and unplugging the unit or by using the reset button
behind the front panel. Hold the escape key until you see the message
’Starting Ethernet Downloader’ at the bottom of the screen. It should
appear right away.