Specifications
5-46 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
5.13.1 Saving and Recalling Settings
The Save Settings soft key can be used to save a copy of the current user settings stored
in EEPROM in the VAX-C. All settings with the exception of the front and rear MAC
addresses and feature key, are included. These stored settings can be used to restore a
system to known user settings.
NOTE:
The EEPROM data does include calibration data, so if using to duplicate user set-
tings on a second system, the calibration data will be copied over as well. As Cal-
ibration data is system specific this will corrupt the calibration; power readings
will be inaccurate until they are recalibrated.
To save the current EEPROM settings, select the Save Settings soft key. A new browser
tab will open showing the EEPROM file in text format. To save the file, from the Save
settings data page, select File> Save Page As
Figure 5-20
Choose where to save EEPROM file, and name the file as desired. Make sure the file
extension is ‘.s19’