Specifications
5/9/13 888-2857-001 5-33
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
5.12.3 Changing Passwords
VAX-C Usernames, Passwords and Session Time Out duration can be changed using
the Tx Home>Exciter Home>Setup>User Settings>Active User screen. Login to the
VAX-C using the netadmin username and password is required to access the User
Management screen.
NOTE:
The netadmin login is an administrative login used to change engineer level user-
names/passwords and session time out. Changes to other transmitter parameters
are not allowed using the netadmin login.
After VAX-C administrator login navigate to Tx Home>Exciter Home>Setup>User
Settings>Active User screen. The Active Users screen in Figure 5-13 on left will be
displayed. Pressing Edit will display the NetAdmin - User Management screen (see
Figure 5-13 on right). The screen shows the current usernames and passwords. Engineer
1 and 2 usernames/passwords a can be changed by typing the new names in the boxes to
right.
The NetAdmin username and password can’t be changed at this time.
Values of Session Time Out from zero to 1440 minutes can be also set here (15 minutes
is a typical setting). If zero is entered there is no limit on time out as long as the user
requests data more frequently than every 5 minutes. If data is not requested within the
five minute window then log out occurs automatically. If a value from 1-1440 minutes
is entered then logout occurs automatically after that time value is exceeded.
If a browser session is closed or a network interruption occurs then the user will be
logged out after 5 minutes. During the 5 minute period no user can log in using the same
password.
Table 5-1 Default Passwords
User Level Username Password
Engineer1 admin admin
Engineer2 user2 pass2
Administrator netadmin harris
Monitor - -