Specifications
5/9/13 888-2857-001 5-29
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
straight slot screwdriver. Remove the VAX-C front cover and remove
the four Phillips screws that hold the VAX-C in the rack. Slide the VAX-
C out of the rack and place it on a sturdy table or bench.
STEP 4 Remove the four Phillips screws on the top, rear of the VAX-C that
secure the cover chassis. Remove the cover by sliding it toward the rear
of the VAX-C and lifting it upward.
STEP 5 Be sure that the connector on the back of the battery backup board aligns
and seats properly on the power supply board connector. The power
supply board standoffs are located on the front left side of the VAX-C.
STEP 6 Install the battery backup board and tighten the four Phillips mounting
screws. The battery backup board, standoffs, and mounting screws are
shown in Figure 5-11.
STEP 7 Replace the VAX-C cover and tighten hardware.
STEP 8 If rack mounted, slide the VAX-C into the rack.
STEP 9 Reconnect all cables to the rear of the VAX-C and tighten connectors as
required.
STEP 10 Restore AC mains power to the VAX-C.
STEP 11 If dual VAX-Cs are used switch the Drive Control to Auto.
NOTE:
Operation of the battery backup board can be monitored on the VAX-C Battery
Backup GUI screen. Refer to the VAX-C technical manual Section 3.11.5 for a
detailed description of the Battery Backup status screen.
STEP 12 End of procedure.
5.11 Changing Feature Key
The feature key unlocks optional features or other modulation standards. It is an alpha-
numeric number. Changes to the feature key are only needed if additional features or
modulation standards are purchased. Contact your Harris sales representative for a
quotation. A new feature key is not required to reload existing software or to load an
updated version of existing software.
Changing modulation type, adding GPS, SFN or MH options require new feature keys.
The LCD control panel on the VAX-C can’t be used to enter a new feature key. The
feature key must be installed using the web GUI. The GUI screen containing the feature
key is shown in Figure 3-25 on page 3-41.