Specifications

5-28 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
Figure 5-11 Battery Backup (UPS) Location
The optional battery backup kit 9710051012G includes:
Qty 4, 3020803006, Screw, Mach M3-0.5 X 6 SEMS
Qty 1, 6600179000, PWA, 9.6V Battery Pack
Instructions:
STEP 1 Turn off transmitter.
STEP 2 Disconnect AC mains power from the VAX-C chassis.
!
WARNING:
REMOVE ALL POWER TO THE VAX-C BEFORE PERFORMING THE FOLLOWING
PROCEDURE.
!
CAUTION:
FOLLOW APPROPRIATE ESD (ELECTROSTATIC DISCHARGE)
PROCEDURES TO PREVENT DAMAGE TO SENSITIVE ELECTRONIC
COMPONENTS WHEN HANDLING CIRCUIT BOARDS.
STEP 3 If the unit is not mounted in a rack proceed to step 4. If rack mounted the
VAX-C must be removed from the rack. Remove cables from the back
of the transmitter using a 5/16” (8mm) open end wrench and a small
Battery