Specifications
5-24 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series
5.8 Air Filter Replacement
Monthly inspection and cleaning of the air filter is recommended. Clean filters more
often in dusty environments. The filters can be easily removed from the front panels and
then cleaned. The filter must be thoroughly dry before reuse. The part number for the
filter material used in the VAX-C is 061-0115-000. The filter material is 1/4" thick,
10ppi.
Figure 5-9 Filter in VAX-C Front Panel
STEP 1 Loosen the two front panel connectors and remove the front panel. The
two filters are captive inside the front panel and slide toward the center
for removal.
STEP 2 Remove the filter material. The notch in the filter material aligns with
the fasteners on the front panel. The filter must be re-installed with the
same orientation.
STEP 3 Clean filter material with compressed air or wash with detergent &
water, or replace as necessary.
!
CAUTION:
DRY THE FILTER MATERIAL THOROUGHLY BEFORE REINSTALLATION.
STEP 4
Reinstall by reversing the order of the above steps.
Filters