WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series 
STEP 10 Slowly raise the transmitter power (using the raise button) until the 
desired power reading is observed on calibrated power meter connected 
to directional coupler at transmitter output (or at the front panel on some 
models).
STEP 11 Navigate to the SETUP>XMTR POWER SETTINGS>POWER 
CALIBRATION MENU. Select FIELD FWD/RFLD and perform 
calibration.
STEP 12 With transmitter set to nominal power output use power meter to confirm 
RTAC sample level (-5dBm optimal).
STEP 13 Use the LCD and front control buttons to navigate to POWER>LINEAR 
and select ADAPT. Then navigate to POWER>NONLINEAR and select 
ADAPT.
STEP 14 Confirm signal quality.
STEP 15 Procedure complete.