Specifications
5-16 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 5 Maintenance and Alignments
Platinum VAX-C Series 
STEP 9 Press the transmitter ON button while monitoring transmitter forward 
power on the external power meter. Monitor reflected power on the LCD 
screen. Slowly raise the power to the desired operational power level 
and allow the transmitter to run for several minutes until output power is 
stable.
STEP 10 Compare the external power meter value with the forward power 
displayed on the LCD screen. If the values do not agree proceed with 
calibration.
STEP 11 Use the LCD screen and control buttons to navigate to the calibration 
menu SETUP> XMTR POWER SETTINGS> POWER CAL> FIELD 
FWD/RFLD. Press Enter one time to highlight the menu then use the up/
down keys to select Field Fwd/Rfld. 
STEP 12 Start the calibration procedure by pressing the Enter button again.
STEP 13 Follow the instructions on the LCD screen and use the power Raise/
Lower buttons to adjust the transmitter output to the desired level.When 
a stable reading is attained on the power meter, select Save and then 
press Enter.
NOTE:
It is helpful to check the RF DAC value displayed (in Hex) on the calibration 
screen. In a system which is properly configured and operating correctly a DAC 
value that exceeds A775 without reaching the desired power level indicates a 
possible problem, verify the system is configured correctly.
STEP 14 Procedure complete.
5.4.2.1  Calibration Errors
If any components in the amplifier section are faulted during the calibration, the system 
will consider it invalid and discard it. Replace any faulty components and perform the 
calibration again.