Specifications
3-106 888-2857-001 5/9/13
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Platinum VAX-C Series
3.15  Status Screens - DVB-T Modulation
Figure 3-78 DVB-T Status Screen (left) -DVB-T Modulator Status Screen 1 (right)
Figure 3-79 Xmtr Home>Exciter Home>Status>DVB-T Modulator (screen 1)
Field Explanation
Active Stream Displays Active Transport stream.
ASI Packet Status In non-hierarchy mode only the high priority (HP) input is used. In 
hierarchy mode both high priority (HP) and low priority (LP) inputs are 
used.
The DVB-T Packet Status sub window displays the status of parameters 
for the four ASI input transport streams shown following:
ASI 1 HP: Primary input, high priority channel
ASI 1 LP: Primary input, low priority channel
ASI 2 HP: Auxiliary input, high priority channel
ASI 2 LP: Auxiliary input, low priority channel
ASI Input   "OK" if input is present, "Error" if input missing.
ASI Uncorr(ected) 
Error
ASI Uncorr(ected) Error displays "OK" if no errors are uncorrected, 
"Error" if some packets had errors that could not be corrected by Reed-
Solomon error correction.
ASI Corrected Error ASI Corrected Error displays "OK" if no errors detected, "Error" if some 
packets had errors that were corrected by Reed-Solomon error correction.
ASI Input Overflow ASI Input Overflow displays "OK" if input data rate OK. "Error" if input 
data rate too high (FIFO overflow).
NIT Status NIT Status displays “NIT OK” if an NIT (Network Information Table) 
packet is detected in input transport stream. If no NIT packets are 
detected then “No NIT” will be displayed.
PCR Status PCR Status displays “PCR OK” if PCR (Program Clock Reference) has 
been detected in transport stream. If no transport stream is present it will 
display “No NIT”. If transport stream is present, but PCR is not present it 
will display “No NIT”.










