Specifications

5/9/13 888-2857-001 3-85
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Platinum VAX-C Series
3.11.3 Transmitter I/O Status screen
Figure 3-54 Status TX I/O Screen
Softkeys
Xmtr Home Displays the Xmtr Home screen.
Exciter Home Pressing this soft key displays Exciter Home Screen, on right Figure 3-12
on page 3-17.
Table 3-58 Xmtr Home> Exciter Home> Status >Transmitter I/O
Field Explanation
Status Sub Window
Power Raise Green is active, blue is inactive, input on pin 1
Power Lower Green is active, blue is inactive, input on pin 2
RF Mute Green is active, Blue is inactive - input on pin 6
Adaptive Reset Resets adaptive correction tables to default values. Green is active, Blue is inactive
- input on pin 10
Adaptive Hold Holds current adaptive correction tables. Green is active, Blue is inactive - input
on pin 11
Table 3-57 Xmtr Home>Exciter Home>Status>DUC/RTAC or UDC/Output
Field Explanation