Specifications

5/9/13 888-2857-001 3-79
WARNING: Disconnect primary power prior to servicing.
Section 3 Operation
Platinum VAX-C Series
Figure 3-49 DAB Setup Screens 5 & 6
Table 3-52 Xmtr Home>Exciter Home>Setup>DAB Modulator>Next x4
Field Explanation
TII Settings
TII Insertion Off/On. Enables/Disables Transmitter Identifier Information (TII). Main identifier
and sub-identifier.
TII Main Identifier Local TII Main Identifier. Range is 0 – 63. When MNSC TII value is set to Local
this setting determines the TII main identifier.
Actual Main Identifier When MNSC TII value is set to ETI this status displays the main identifier being
broadcast.
TII Sub Identifier Local TII Sub Identifier. Range is 0 – 23. When MNSC TII value is set to Local
this setting determines the TII sub-identifier.
Actual Sub Identifier When MNSC TII value is set to ETI the actual TII sub-identifier being
broadcast is displayed here.
Local Identifier Sets the transmitter ID used as an identifier for the MNSC. In this instance
messages addressed to 17 will be decoded.
Scrambling
Scrambling Off/On. Enables/Disables scrambling.
Scrambling Key De-scrambling key entry. Range is 0 to 255.
Legacy OFE660 SFN Compliance
OFE660 Compliance On/ Off. Controls setting of M2X SFN compatibility mode. Allows SFN
compatibility with legacy systems. Off is the default setting.