Technical information
Console Serial Line
Interface standards EIA RS–423–EIA V.10 X.26
EIA RS–232–C/CCITT V.28
DEC–423
Data format 1 start bit, 8 data bits, 0 parity bits, 1 stop
bit
Baud rates 300; 600; 1200; 2400; 4800; 9600; 19,200;
38,400
Configuration Information
Form factor Quad height
Power requirements +5 Vdc, 4.8 A; +3.3 Vdc, 0.27 A
+12 Vdc (alone), 0.14 A; +12 Vdc (with
H3602), 0.55 A; –12 Vdc, 0.04 A
Power consumption 42.6 W
Bus loads 3.5 ac; 1.0 dc
Operating System Support
VMS Version 5.4-2
VAXELN Version 3.2
Diagnostic Support
MicroVAX Diagnostic Monitor Release 134 and later
Self-tests Yes
Related Documentation
EK–KA660–TM KA660 CPU Technical Manual
EK–398AA–MM KA660 CPU System Maintenance
Base System Description 1–17