Technical information
Table 1–2 (Cont.): Console I/O Mode Commands
Command Action
TEST Invokes a diagnostic test program specified by the test number
you enter. If you enter a test number of 0 (zero), all tests allowed
to be executed from the console terminal are executed. The
console accepts an optional list of up to five additional hexadecimal
arguments.
UNJAM Performs an I/O bus reset, by writing a 1 (one) to IPR 55 (decimal).
X Loads or unloads (that is, writes to memory or reads from memory)
the specified number of data bytes through the console serial line
(regardless of console type), starting at the specified address. For
use by automatic systems communicating with the console.
Examples 1–1 through 1–6 show sample displays for the commonly used
commands SHOW and SET.
The SET command sets the parameter to the value you specify. The SHOW
command displays the console parameter you specify.
Example 1–1: SHOW QBUS Display
>>> SHOW QBUS
Scan of QBUS I/O Space
-200000DC (760334) = 0000 (300) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK
-200000DE (760336) = 0AA0
-200000E0 (760340) = 0000 (304) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK
-200000E2 (760342) = 0AA0
-200000E4 (760344) = 0000 (310) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK
-200000E6 (760346) = 0AA0
-20001468 (772150) = 0000 (154) TLZ04/TQK70/RRD40/RQC25/KFQSA-DISK
-2000146A (772152) = 0AA0
-20001F40 (777500) = 0020 (004) IPCR
Example 1–1 (continued on next page)
Base System Description 1–9