Technical data

Table 3–7: TLZ04 Drive Indicators (Normal Conditions)
Indicator Color(s) Meaning
Tape Indicates status of cassette tape as follows.
Solid green Tape loaded.
Solid yellow Tape loaded and write protected.
Drive Indicates status of TLZ04 drive as follows.
Solid green Drive ready/power on.
Flashing green Drive active.
Flashing yellow Power-up self-test in progress.
Table 3–8: TLZ04 Drive Indicators (Abnormal Conditions)
Indicator Color(s) Meaning
Tape Slow flashing
green or yellow
Excessive tape errors. Use the head cleaning cassette.
If failure repeats itself, use another cassette tape.
Tape Flashing yellow
1-3 times
Power-up self-test failed.
Drive Solid yellow Power-up self-test failed.
Drive and Tape Solid yellow High humidity. Adjust operating environment.
3.1.4.1 Proper Handling of Cassette Tapes
Digital Equipment Corporation recommends that you use TLZ04 cassette
tapes. To ensure optimal performance from your cassette tapes, observe
the following guidelines when handling them.
Avoid placing the cassette tapes near sources of electromagnetic
interference, such as terminals, and video or X-ray equipment.
Emissions from such equipment can erase data on the tape.
Keep cassette tapes out of direct sunlight and away from heaters and
other sources of heat.
Store cassette tapes (and cleaning cassette) where the room
temperature is between 5°C and 32°C (40°F and 90°F).
Store cassette tapes in a dust-free environment where the relative
humidity is 20% to 60%.
3–32 VAX 4000 Model 200 (BA430) Operation