Technical data

Figure 3–5: Select Single Device Test Menu
MAIN MENU Release nnn Version xx.xx
SELECT SINGLE DEVICE TEST
Select the device number to be tested. The functional tests
will be run followed by the exercisers for 4 minutes.
1 - CPUA - MicroVAX CPU
2 - MEMA - MicroVAX memory system
3 - PDIA - SHAC DSSI Subsystem
4 - SGCA - Second Generation Ethernet Controller
5 - No Dg TKA - Diagnostic not loaded.
Type the number; then press the RETURN key,
or type 0 and press the RETURN key to return to the Main Menu. >
NOTE: Because of the similarity of some communication options, MDM sees
them as the same device. A CXA16 and CXB16 appear the same to MDM. A
generic device name, DH–CX0, is listed for such options, and the last letter
in each name shows the difference. For example, DH–CX0A indicates one
option, DH–CX0B a second, and so forth.
Select a device for testing by typing its number and
Return
.
After you press
Return
, your system configures the device diagnostics and
testing begins. If the device passes the functional test, a message to that
effect appears and the exerciser test begins. The exerciser test runs for
approximately 4 minutes.
Figure 3–6 shows an example of a successful test.
Running the MicroVAX Diagnostic Monitor (MDM) 3–15