Technical data

3.5.3 Display the System Utilities Menu Option
The Display the System Utilities Menu option displays the System Utilities
Menu. If system utilities in addition to the IOADDRES function are
available on your system, they are listed on that menu.
After you select this option, the diagnostics are prepared for testing. If this
is the first option you selected, the diagnostics are loaded. Loading takes
several minutes. After loading completes, you are prompted to press
Return
.
After you press
Return
, the System Utilities Menu appears. Figure 3–4 shows
that menu for a system with two RRD-series drives.
Figure 3–4: System Utilities Menu
MAIN MENU
SYSTEM UTILITIES
Utility selections are:
1 - IOADDRES
2 - RRAA - Update drive unit number for RRD40 controller A.
3 - RRAB - Update drive unit number for RRD40 controller B.
NOTE: If your system does not have an RRD-series drive connected to a
KRQ50 controller, only one function, IOADDRES, is available.
Select a function by typing its number and
Return
.
3.5.3.1 IOADDRES Function
NOTE: The IOADDRES function is for users of Industrial VAX systems. It
is described in the Industrial VAX troubleshooting manual.
The IOADDRES function gives you a list of standard CSR addresses and
interrupt vectors that MDM uses in testing devices. The first available CSR
and interrupt vector for configuring devices with a nonstandard address is
also given. IOADDRES does not look at devices on the bus; it lists devices
supported by Digital Customer Services.
The devices in your system were configured at the factory. Any new
devices added to your system should be configured by a Digital service
representative.
Running the MicroVAX Diagnostic Monitor (MDM) 3–13