Technical data
5. Turn on your system (and the disc drive).
6. Insert the disc caddy into the disc drive:
a. Remove the disc from its package.
b. Insert the disc into the caddy.
c. Insert the caddy into the drive slot:
For an RRD40 drive, push the caddy in until it stops. Then
withdraw the caddy. The disc remains in the drive.
For another RRD-series drive, the caddy stays in the drive. Do
not remove it.
7. Tell your system to load MDM from the disc:
For a KZQSA adapter, enter the command BOOT DKxn, where x is
the adapter port letter and n is the drive unit number.
For a KRQ50 controller, enter the command BOOT/100 DUxn,
where x is the controller port letter and n is the drive unit
number. Then, when your system displays Bootfile:, enter
[SYS0.SYSEXE]MDMCD.SYS (the boot file name).
Loading MDM takes several minutes. Section 3.4 describes the display
you see after loading completes.
8. After loading completes, place all hard disks and RF-series ISEs on
line.
3.4 MDM Introductory Display
After MDM is loaded, the introductory display appears. Make sure the date
and time in that display are correct.
• If the date and time are correct, press
Return
to continue.
• If the date and time are not correct, type the correct date and time
using the format shown in the display. For example, enter 10–JUN–
1991 02:30 and press
Return
to continue.
The Main Menu appears. Section 3.5 describes the options on that menu.
3–8 VAX 4000 Model 200 Troubleshooting and Diagnostics