Technical data

5. Turn on your system (and the disc drive).
6. Insert the disc caddy into the disc drive:
a. Remove the disc from its package.
b. Insert the disc into the caddy.
c. Insert the caddy into the drive slot:
For an RRD40 drive, push the caddy in until it stops. Then
withdraw the caddy. The disc remains in the drive.
For another RRD-series drive, the caddy stays in the drive. Do
not remove it.
7. Tell your system to load MDM from the disc:
For a KZQSA adapter, enter the command BOOT DKxn, where x is
the adapter port letter and n is the drive unit number.
For a KRQ50 controller, enter the command BOOT/100 DUxn,
where x is the controller port letter and n is the drive unit
number. Then, when your system displays Bootfile:, enter
[SYS0.SYSEXE]MDMCD.SYS (the boot file name).
Loading MDM takes several minutes. Section 3.4 describes the display
you see after loading completes.
8. After loading completes, place all hard disks and RF-series ISEs on
line.
3.4 MDM Introductory Display
After MDM is loaded, the introductory display appears. Make sure the date
and time in that display are correct.
If the date and time are correct, press
Return
to continue.
If the date and time are not correct, type the correct date and time
using the format shown in the display. For example, enter 10–JUN–
1991 02:30 and press
Return
to continue.
The Main Menu appears. Section 3.5 describes the options on that menu.
3–8 VAX 4000 Model 200 Troubleshooting and Diagnostics