Technical data

6. Set the Break Enable/Disable switch to disable (down, dot outside
circle).
The system displays a banner and then prompts you for the date and
time.
VAX/VMS Version Vn.n Major version id = 1 Minor version id = 0
Please enter date and time (DD-MMM-YYYY HH:MM):
7. Enter the date and time in the format shown. For example:
Please enter date and time (DD-MMM-YYYY HH:MM): 03-JUL-1991 12:00
Return
Some messages are displayed, followed by a prompt:
=====================================================
Modifying Factory Installed Software for Customer Use
%SET-I-NEWAUDSRV, identification of new audit server......
%LICENSE-F-EMTLDB, license database contains no license records
.
.
.
Do you want to enter Customer’s cluster and password information(Y/N)?
8. Refer to the appropriate section to complete the startup procedure for
a:
Standalone system, Section A.2.1
Simple VAXcluster network, Section A.2.2
Dual-host system or complex VAXcluster network, Section A.2.3
A.2.1 Modifying FIS for a Standalone System
The following procedure modifies FIS for a standalone system.
Do you want to enter Customer’s cluster and password information(Y/N)?
1. Enter Y (type Y and
Return
).
The system asks you to confirm the date and time.
The system time is dd-mmm-yyyy hh:mm:ss:ss
Is this correct? (Y/N)
2. If the date and timeareincorrect, enter N. With that answer, the system
reprompts you to enter the correct date and time and then to review it.
If you enter Y, the system displays the following prompt.
Will this node be a cluster member (Y/N)?
3. Enter N.
Starting and Modifying VMS Factory-Installed Software A–3