Technical information

control units are never reset and replaced at the same time.
E03
-
Result: Defective Component
Defective component:
K117 Control Unit - Immobiliser
or
A4 Control Unit - Multec
Important:
Reset concerned control unit (engine or immobiliser control unit) with diagnostic
tester before replacing. Select immobiliser in the diagnostic tester and call up the
corresponding test in the menu ADDITIONAL FUNCTIONS. Ensure that both
control units are never reset and replaced at the same time.
C-03 - System Status Information
E01
-
Result: Defective Component
Defective component:
A17 Control Unit - Immobiliser
Important:
Reset concerned control unit (engine or immobiliser control unit) with diagnostic
tester before replacing. Select immobiliser in the diagnostic tester and call up the
corresponding test in the menu ADDITIONAL FUNCTIONS. Ensure that both
control units are never reset and replaced at the same time.
C-04 - Switched System Voltage Circuit
T01
-
Check: Short to Ground/Interruption of Voltage Supply Circuit
Work Order Description
Nominal Value
Ignition OFF
Disconnect wiring harness connector from:
A17 Control Unit - Immobiliser
Ignition ON
Measure voltage between the following
terminals:
A17 Control Unit - Immobiliser
Wiring harness connector (wiring harness
side) terminal 5
&
Ground
greater than 11 V
Yes:E01
No:T02
T02
-
Check: Component
Work Order Description
Nominal Value
Page
44
of
63