Technical information
G1 Battery
Wiring harness connector (component side)
terminal 30
&
Ground
Yes:T02
No:E14
T02
-
Check: Short to Ground/Interruption of Voltage Supply Circuit
Work Order Description
Nominal Value
Measure voltage between:
X13 Diagnostic Link
Wiring harness connector (wiring harness
side) terminal 16
&
Ground
greater than 11 V
Yes:T03
No:T09
T03
-
Check: Circuit Interruption of Ground Circuit
Work Order Description
Nominal Value
Measure voltage between:
X13 Diagnostic Link
Wiring harness connector (wiring harness
side) terminal 16
&
X13 Diagnostic Link
Wiring harness connector (wiring harness
side) terminal 4,5
greater than 11 V
Yes:T04
No:E07
T04
-
Check: Component
Work Order Description
Nominal Value
Check the following component for proper
operation:
Diagnostic tester
Test okay?
Yes:T05
No:E06
T05
-
Check: Interruption of Voltage Supply Circuit
Work Order Description
Nominal Value
Disconnect wiring harness connector from:
A17 Control Unit - Immobiliser
Measure voltage between:
A17 Control Unit - Immobiliser
Wiring harness connector (wiring harness
greater than 11 V
Page
36
of
63
12/25/2005
file://C:\Program%20Files\cosids\DATA\TMP\TmpPrn359232138.HTM