Technical data
OPEL MOVANO (X62)
106 – CELL WIRING CONNECTION OPTION WRF
Note:
Subject to errors and technical amendments. The electronic version of the body guidelines is the decisive source of
up-to-date data on body guidelines (online body guidelines). Data status September 2010
16-WAY CONNECTOR
ASSIGNMENT OF 16-WAY CONNECTOR
N.B.:
The width of the contact for ways 1, 8, 9 and 16 is 2.8 mm; the width for the other ways is 1.5 mm.
Way number Assignment
Way 1 (20BK) Analogue door closing control signal (
wire cross section 2 mm²
)
Way 2 (87T) Logical boot lock switch information signal (
wire cross section 0.35 mm²
)
Way 3 (BPT2)
Delayed +12
V 2
A power supply for courtesy lights, controlled by the passenger
compartment ECU (UCH) (wire cross section 0.5 mm²)
Way 4 (LPG) 3 A left-hand side light power supply (wire cross section 0.5 mm²)
Way 5 (34D)
+ right-hand rear speaker (wire cross section 1 mm²)
Way 6 (34B)
- left-hand rear speaker (wire cross section 1 mm²)
Way 7 (BMT1)
“Engine running” information, 10
A fuse shared by ways 7 and 8 (wire cross section
1.5 mm²)
Way 8 (SBP4)
“+12
V offloaded current dist
ribution power supply”, 10
A fuse shared by ways 7
and 8 (wire cross section 1.5 mm²)
Way 9 (142K) Analogue door closing control signal (
wire cross section 2 mm²
)
Way 10 (65A) 5 A 3
rd
brake light power supply (wire cross section 0.5 mm²)
Way 11 (13M)
Pr
ogressive ground for 2
A courtesy lights, controlled by the passenger
compartment ECU (UCH) (wire cross section 0.35 mm²)
Way 12 (LPD) 3 A right-hand side light power supply (wire cross section 0.5 mm²)
Way 13 (34C)
- right-hand rear speaker (wire cross section 1 mm²)
Way 14 (34A)
+ left-hand rear speaker (wire cross section 1 mm²)
Way 15
Reserve
Way 16 (20W) Analogue door super lock signal (
wire cross section 2 mm²
)
30