Technical data

OPEL MOVANO (X62)
106 – CELL WIRING CONNECTION OPTION WRF
Note:
Subject to errors and technical amendments. The electronic version of the body guidelines is the decisive source of
up-to-date data on body guidelines (online body guidelines). Data status September 2010
2-WAY CONECTOR
This connector is strictly identical to the one described in technical data chapter 104-Connector for the
‘’KPD’’ option adaptation.
The maximum permanent current of this power supply must not exceed 40A. This line is protected by 50A
fuse F6 in the engine interconnections unit.
ASSIGNMENT OF 2-WAY CONNECTOR WAYS
Way number Assignment
Way 1 (BP23)
+12 V direct battery power supply for maximum consumption of 40 A (wire cross
section 7 m).
50 A fuse protection.
Way 2 (MAN32)
Ground (wire cross section 7 mm² large enough to adapt to the current of the +12 V
battery).
Important:
This power supply is connected directly to the battery. The vehicle is therefore not protected by
the energy management system. Risk of battery draining.
The counterpart to this connector is already fitted to the wiring but it is still necessary to obtain the
contacts for this connector.
Connector Wire cross section Contact part number
Supplier
reference
Supplier
8200784203
3 to 6 mm² 8200071946 P790861 TYCO
7 to 10 mm² 8200071948 P790862 TYCO
28