Technical data
OPEL MOVANO (X62)
105 – CAN BUS- INTERFACE MODULE, “KC6” OPTION
Note:
Subject to errors and technical amendments. The electronic version of the body guidelines is the decisive source of
up-to-date data on body guidelines (online body guidelines). Data status October 2012
GENERIC DIAGRAM OF RELAY CONTROL BY BINARY OUTPUT
A: Complementary Adaptations Unit
B: Dry contact output for information recovery
C: Binary output to be relayed on the Complementary Adaptations Unit.
D: The relay’s power supply must not be taken directly from the + battery.
E: Maximum current of 200 mA
F: Relay
For example, the following relays may be used:
40 Ampere relay, CARTIER reference = 20 240 041
20 Ampere relay, CARTIER reference = 29 201 041
N.B.: It is vital that these relays be fitted with a freewheel diode.
3) Analogue outputs (PWM)
These 2 outputs comply with Renault specification 36-00-100 UNI-B (45 mA, 10.5 at 16V)
1
4 5
2
3
B
B
A
C
D
E
F
24