Technical data

OPEL MOVANO (X62)
104 – 6 PIN -CONNECTOR FOR CONVERSIONS, OPTION KPD
Note:
Subject to errors and technical amendments. The electronic version of the body guidelines is the decisive source of
up-to-date data on body guidelines (online body guidelines). Data status August 2012
ASSIGNMENT OF 6 WAY-CONNECTOR
Way number Assignment
Way 1 (3ADJ) Accelerated idle control (wire cross section 0.5 mm²)
Way 2 (BMT1) “Engine running” information
Shared 10 A fuse
(wire cross section 1 mm²)
Way 3 (SBP4)
Power supply + 12
V off
distribution
Way 4 (MAN32)
Ground (wire cross section 1.5 mm² large enough to adapt to the +12V offloaded
current distribution)
Way 5 Reserve
Way 6 Reserve
The counterpart to this connector is available from the Opel dealer network.
CONNECTION KIT
N.B.:
The permanent accumulated currents of the following 2 ways must not exceed 8 A:
-
Way 2: "Running Engine" information
-
Way 3: “+ 12 V current distribution”. (activated from the +ACC (+ accessory) position, 1st notch on
the ignition key).
These ways are protected by 10 A fuse F28 in the passenger compartment fuse and relay box (BFRH).
For more power, ways 2 and 3 need to be relayed.
When the engine is off, the energy management system can offload these functions to save enough battery
power to start the vehicle.
13