User manual

1. Loosen the safety screw [7] on the tube clamp of the main tube [4]. Pull the safety bolt
[12] out of the square tube [8] and crank the square tube all the way down with the
crank [9].
2. Fix the position of the square tube with the safety screw [7].
3. Loosen the safety screw [5] on the tube clamp of the square tube [8]. Pull the safety bolt
[13] out of the upper extension tube [6] and crank the upper extension tube all the way
down with the crank [9].
4. Fix the position of the extension tube with the safety screw [5].
5. Remove the spotlights. When dismounting, pay attention to an even weight distribution
to reach a centric load of the stand.
6. Loosen the safety screw of the mount and detach the crossbar.
7. Loosen the safety screw [3] of the adjustable foot, pull out the corresponding safety bolt
and push the foot completely into the tube. Fix the position with the safety screw [3].
8. Loosen the safety screw [1 ] on the carriage. Pull the safety bolt [11] out of the main tube
[4] and fold up the stand feet [2].
9. Fix the position with the safety screw [1] on the carriage.
10. Pack all parts of the system in their original package, as possible, and store the package
in a dry place protected against moisture.
Dismounting
Operating
18
Wind Up 85 kg TÜV
lighting stand