Symptom Remedy
The unit does not work, no light,
the display is dark
Check the mains connection and the main fuse.
Apparently no function despite
proper power supply
Check if the unit is in DMX mode or in ‘slave’ mode. If so,
check the unit in another mode.
No response to the DMX con‐
troller
1. If the unit is in DMX mode and the display ashes, no
DMX signal is received. Check whether the DMX con‐
troller is switched on. Check the DMX connectors and
cables for proper connection.
2. If the unit is in DMX mode and a DMX controller is
connected and turned on, a dot on the fourth digit of
the display will ash. If it doesn't, no valid DMX signal is
received. Check whether the DMX controller is switched
on. Check the DMX connectors and cables for proper
connection.
3. If the display dot is ashing but there is still no
response, check the address settings and the DMX
polarity.
4. Try using another DMX controller.
5. Check whether the DMX cables run near or parallel to
high-voltage cables that may cause damage or interfer‐
ence to a DMX interface circuit.