User manual
Table Of Contents
- Table of contents
- 1 General information
- 2 Safety instructions
- 3 Features
- 4 Installation
- 5 Starting up
- 6 Connections and operating elements
- 7 Operating
- 7.1 Starting the device
- 7.2 Navigating the menu
- 7.3 Operating on the unit
- 7.3.1 Setting the DMX address
- 7.3.2 Setting the DMX mode
- 7.3.3 ‘Automatic mode’
- 7.3.4 Operating mode ‘Sound control’
- 7.3.5 Master / slave mode
- 7.3.6 Setting colour macro
- 7.3.7 Setting dimmer and strobe effect for CW LEDs (WhiteBar)
- 7.3.8 Setting an individual mixed colour
- 7.3.9 Rotating the Display
- 7.3.10 Display lighting
- 7.3.11 Behaviour on DMX control failure
- 7.3.12 Dimmer curve
- 7.3.13 Key lock
- 7.3.14 Resetting the device to factory defaults
- 7.3.15 PWM (pulse width modulation)
- 7.3.16 Firmware version display
- 7.3.17 Operating hours display
- 7.3.18 LED temperature display
- 7.4 Menu overview
- 7.5 Functions in 3-channel mode
- 7.6 Functions in 6-channel mode
- 7.7 Functions in 12-channel mode
- 7.8 Functions in 16-channel mode
- 7.9 Functions in 56-channel mode
- 7.10 Functions in 68-channel mode
- 8 Technical specifications
- 9 Plug and connection assignment
- 10 Troubleshooting
- 11 Cleaning
- 12 Protecting the environment
4.
Use or to choose between ‘Hold’ (last DMX value is held), ‘Blackout’ (spot‐
light is switched o) or ‘ManualMode’ (emergency lighting is turned on) to
make the setting to be used if the DMX control fails.
5.
Press to accept the selection.
7.3.12 Dimmer curve
1.
Press to activate the main menu.
2.
Press or repeatedly until the display shows ‘Settings’ . Conrm with .
3.
Press or repeatedly until the display shows ‘Dimmer Curve’ . Conrm with
.
4.
Use or to select the desired dimmer curve.
Display Meaning
‘Linear’ Linear course
‘Exponential’ Exponential course
(Square curve with a at prole at the beginning and a
steep prole at the end)
‘Logarithmic’ Logarithmic course
(Inverted quadratic curve with a steep course at the
beginning and a at course at the end)
‘S Curve’ S-curve shaped course
(Non-linear curve with a distinctive at course at the
beginning and end)
5.
Press to accept the selection.
7.3.13 Key lock
1.
Press to activate the main menu.
2.
Press or repeatedly until the display shows ‘Settings’ . Conrm with .
3.
Press or repeatedly until the display shows ‘AutoLock’ . Conrm with .
4.
Use or to choose between ‘On’ (keylock on) and ‘O’ (keylock o).
5.
Press to accept the selection.
6.
Simultaneously press and for 5 seconds if you want to activate the input
while the keylock is activated.
7.3.14 Resetting the device to factory defaults
1.
Press to activate the main menu.
2.
Press or repeatedly until the display shows ‘Settings’ . Conrm with .
3.
Press or repeatedly until the display shows ‘Factory Reset’ .
ð
The display shows the message ‘Reset Now’ .
4.
Press to reset the device to factory default setting.
Operating
18
Colors NerveStrobe HP
Stroboscope