Solutions for Demanding Applications VarTech Systems Inc. Industrial CRT and Flat Panel Displays 14” Console Mount Auto Sync Color Monitor MODEL NUMBER: VT14B-C1 User’s Guide Read these instructions completely before attempting to operate your new Color Display.
TABLE OF CONTENTS Sections Page Warning and Caution 1 Operating Instructions 2 5BNC Connectors 3 Controls 4 Mode Operations 5 Chassis Mount Mechanical 6 Specifications 7 14” Fast Scan Series User Guide 150-049
Section 1 SAFETY WARNINGS The following warnings and cautions are for your safety, for the prevention of injury from electric shock and for the safe operation of the monitor. Please read them carefully. ♦ ♦ ♦ ♦ ♦ ♦ ♦ Do not block the ventilation slots or insert any objects into the monitor through them. Do not spill water onto the monitor or spray aerosol cleaners directly onto its surfaces when cleaning. Always position and operate the monitor on a stable and safe surface.
Section 2 OPERATING INSTRUCTIONS Video Signal Correction The monitor is supplied with a 15pin HD connector (HD15F), 5BNC input connectors and an optional 9pin connector (DB9F) arranged as shown below: R H V G B DIP SWITCH ON 75Ω ∗ OFF HiZ ON DISABLED OFF ENABLED* DDC *Factory Default 1 15 15 Pin D CONNECTOR: This is an industry standard connector providing easy connection to VGA type video sources.
BNC CONNECTORS These connectors allow the monitor to work with Red, Green and Blue coaxial cable. The monitor synchronization may be Sync on Green, Composite sync or Separate Horizontal and Vertical sync. The “H” input is used for composite sync. Video inputs: Red, Green, Blue. 0.7v p-p into 75 Ω Sync inputs: 1. Sync on green 0.3v p-p into 75Ω superimposed onto green video. (3 wire) 2. Composite sync TTL level, positive or negative, combined horizontal or vertical sync. (4 wire) 3.
Section 3 DIGITAL CONTROLS DIGITAL CONTROLS The digital controls are located on the rear side of the monitor. LED Digital Display Control VT Switch ∗ Function + Contrast 5 + Brightness — + Horizontal Position — + Horizontal Size — + Vertical Position (keystone)* — + Vertical Size (pincushion)* — — Press Function button. LED will blink allowing for keystone & pincushion adjustments.
MODE OPERATIONS In the normal mode of operation, the LED is not flashing. Disable Keypad 1. Press and release the FUNCTION (upper right) switch. The LED will now be flashing. 2. Simultaneously press the FUNCTION and the VT (upper left) switches. Note that the VT switch is not labeled. The LED will momentarily be off and then resume flashing. 3. Press and release the FUNCTION (upper right) switch. The LED will not be flashing. 4. To enable the keypad, repeat the above steps. Factory Default Settings 1.
Section 4 SPECIFICATIONS ENGINEERING SPECIFICATIONS Size 14” Pitch .28mm Resolution Capabilities CGA to XGA Active Display Area 11” x 8.3” / 279.4mm x 210.82mm Deflection Angle 90º Phosphor Medium Short B22 Power Source 90 - 265 volts AC autoranging 50/60 Hz, 1.5 amps ac Power Consumption 90 Watts Horizontal Frequency 30kHz to 54kHz Vertical Frequency 45Hz to 100Hz Bandwidth 90MHz Video Input Connector HD15(F) and 5BNC Video Input Signal Analog 0.
VARTECH SYSTEMS INC. HEADQUARTERS 11529 Sun Belt Ct. Baton Rouge, Louisiana 70809 Toll-Free: 800.223.8050 International Phone: 001.225.298.0300 Fax: 225.297.2440 E-mail: sales@vartechsystems.com www.vartechsystems.com 14” Fast Scan Series User Guide 150-049-001 6.17.