Solutions for Demanding Applications VarTech Systems Inc. Industrial CRT and Flat Panel Displays VT14A-C1 Console Mount Auto Sync Color Monitor User’s Guide Read these instructions completely before attempting to operate your new Color Display.
TABLE OF CONTENTS Sections Page 1 Warning and Caution 2 Video Connections 2-3 5BNC Connectors 4 Controls 5 Mode Operations 6 4 Chassis Mount Mechanical 7 5 Specifications 8 3 1
Section 1 SAFETY WARNINGS The following warnings and cautions are for your safety, for the prevention of injury from electric shock and for the safe operation of the monitor. Please read them carefully. ♦ ♦ ♦ ♦ ♦ ♦ ♦ Do not block the ventilation slots or insert any objects into the monitor through them. Do not spill water onto the monitor or spray aerosol cleaners directly onto its surfaces when cleaning. Always position and operate the monitor on a stable and safe surface.
Section 2 VIDEO CONNECTIONS VIDEO CONNECTIONS Video Signal Correction The monitor is supplied with a 15pin HD connector (HD15F) and 5BNC input connectors arranged as shown below: ON OFF 1 1 9 DIP SWITCH A * * *Factory Default R H ON OFF V G 1 DIP SWITCH B * * B DDC 1 15 15 Pin D CONNECTOR: This is an industry standard connector providing easy connection to VGA type video sources.
VIDEO CONNECTIONS CONT. 9 Pin D CONNECTOR: This connector allows the monitor to work with TTL video signals. It is compatible with industry standard EGA and CGA signals. In addition it can be configured for 3, 4 or 6 bit TTL video from other types of video source.
5BNC CONNECTORS These connectors allow the monitor to work with Red, Green and Blue coaxial cable. The monitor synchronization may be Sync on Green, Composite sync or Separate Horizontal and Vertical sync. The “H” input is used for composite sync. Video inputs: Red, Green, Blue. 0.7v p-p into 75 Ω Sync inputs: 1. Sync on green 0.3v p-p into 75Ω superimposed onto green video. (3 wire) 2. Composite sync TTL level, positive or negative, combined horizontal or vertical sync. (4 wire) 3.
Section 3 DIGITAL CONTROLS DIGITAL CONTROLS The digital controls are located on the rear side of the monitor. Normal Mode Controls Operates the functions when the LED power is on continuously. Function Mode Controls Operates the functions when the LED is flashing. LED Function Key Press to switch between normal mode (LED will stop flashing) and function mode (LED will start flashing).
MODE OPERATIONS In the normal mode of operation, the LED is not flashing. Disable Keypad 1. Press and release the FUNCTION (upper right) switch. The LED will now be flashing. 2. Simultaneously press the FUNCTION and the VT (upper left) switches. Note that the VT switch is not labeled. The LED will momentarily be off and then resume flashing. 3. Press and release the FUNCTION (upper right) switch. The LED will not be flashing. 4. To enable the keypad, repeat the above steps. Factory Default Settings 1.
Section 5 SPECIFICATIONS ENGINEERING SPECIFICATIONS Size 14” Pitch .28mm Deflection Angle 90º Phosphor Medium Short B22 Resolution Capabilities CGA to SVGA Active Display Area 11.25” x 8.25” / 285.75mm x 209.55mm Power Source 90 - 265 volts AC autoranging 50/60 Hz, 1.5 amps ac Power Consumption 90 Watts Horizontal Frequency 15kHz to 40kHz Vertical Frequency 40Hz to 100Hz Bandwidth 65MHz Video Input Connector HD15(F) and 5BNC, Optional DB9 Video Input Signal Analog 0.
VARTECH SYSTEMS INC. HEADQUARTERS 11529 Sun Belt Ct. Baton Rouge, Louisiana 70809 Toll-Free: 800.223.8050 International Phone: 001.225.298.0300 Fax: 225.297.2440 E-mail: sales@vartechsystems.com www.vartechsystems.com 150-048-002 5.23.